Keterangan Kode Error AC Panasonic Jenis Inverter Terlengkap
H00: Tdk ada memori kegagalan
H11: Komunikasi abnormal dlm/luar ruangan
H12: Kapasitas unit dlm tdk cocok
H14: Abnormalitas sensor suhu udara pengambilan dlm ruangan
H15: Abnormalitas sensor suhu kompresor
H16: Abnormalitas transformer arus (CT) luar ruangan
H19: Kunci mekanisme motor kipas dlm ruangan
H23: Abnormalitas sensor suhu penukar panas dlm ruangan
H25: Abnormalitas e-ion dlm ruangan
H27: Abnormalitas sensor suhu udara luar ruangan
H28: Abnormalitas sensor suhu penukar panas luar ruangan
H33: Abnormalitas salah hubung dlm/luar ruangan
H38: Ketdk cocokan dlm/luar ruangan (kode merek)
H58: Abnormalitas sensor gas dlm ruangan
H59: Abnormalitas rensor eco patrol
H98: Abnormalitas sensor tekanan tinggi dlm ruangan
H99: Perlindungan thdp pembekuan unit yg beroperasi di dlm ruangan
F11: Abnormalitas switching katup 4-arah
F90: Gagal komunikasi komputer mikro sistem dan kompresor
F91: Abnormalitas daur pendinginan
F93: Putaran kompresor abnormal
F96: Perlindungan thdp panas berlebih pd modul transistor daya
F97: Perlindungan thdp panas berlebih pada kompresor
F98: Perlindungan thdp arus berjalan total
F99: Deteksi puncak arus searah (DC) luarruangan
Nb: *untuk model pendinginan saja,ini merupakan petunjuk bilamana sensor penukar panas di dlm ruangan atau sensor pengambilan udara dlm ruangan mengalami abnormalitas.
KODE ERROR AC SHARP:
E0 : Water pump malffunction
E : High pressure protection of compressor
E2 : Indoor anti-frozen of compressor
E3 : Low pressure protection of compressor
E4 : Air discharge high-temperature protection of compressor
E5 : Overload protection of compressor
E6 : Transmit malfunction
E8 : Indoor fan protection
E9 : Water flow protection
F0 : Malfunction of indoor environment sensor at air return vent
F : Evaporator sensor malfunction
F2 : Condenser sensor malfunction
F3 : Outdoor environment sensor malfunction
F4 : Malfunction of air discharge sensor
F5 : Malfunction of environment sensor on displayer
FF : Connected control communications Failure
EE : Buttons are locked (not failure)
KODE ERROR AC CHANGHONG:
E1 power module overheating, overcurrent, short circuit
E2 current sensor sensing current is too small
E4 when the press temperature sensor heating temperature exceeds 120 ℃
E5 overcurrent protection
E6 outdoor temperature sensor failure
E7 outdoor coil sensor failure
Ea super-voltage power supply
Ec cooling when the outdoor heat exchanger sensor temperature exceeds 70 ℃ Protection
Ee chip EEPROM data read errors
F1 room temperature sensor failure
F2 indoor coil sensor failure
F4 for heating the indoor coil sensor 超过 72 ℃ Protection
F5 cooling when the indoor coil temperature sensor is lower than 0 ℃ following protection
F7 indoor board communication failure with the control panel
KODE ERROR AC TCL:
EO = In and out communication failure
EC = Outdoor communication failure
E1 = Outdoor sensor
E2 = Indoor coil temperature sensor
E3 = Outdoor coil temperature sensor
E4 = System abnormity
E5 = Type mismatch
E6 = Indoor fan motor
E7 = Outdoor temperature sensor
E8 = Discharge temperature sensor
E9 = Invert module abnormity
EF = Outdoor fan motor (DC)
EA = Current sensor
EE = EEPROM failure
EP = Top of compressor temperature switch
EU = Voltage sensor